

There are numerous ways of monitoring system load average including uptime which shows how long the system has been running, number of users together with load averages: $ uptimeĠ7:13:53 up 8 days, 19 min, 1 user, load average: 1.98, 2.15, 2.21ĭisplay Running Linux Processes top - 12:51:42 up 2:11, 1 user, load average: 1.22, 1.12, 1.26 But this is not the case with Linux, it includes processes in uninterruptible sleep states those waiting for other system resources like disk I/O etc.

The electricity network in South Africa is controlled to a frequency of 50Hz. South Africa’s peaking power stations are hydroelectric, hydro pumped storage and gas turbine stations. Peaking power stations can react quickly to changes in demand and provide power to supplement that generated by base load stations. In summer, air conditioning has the same effect. In winter, record evening peaks occur with the increased use of domestic heating appliances. The morning peak is a combination of industrial and domestic demand whereas the evening peak is mainly domestic. In South Africa, peak demand periods occur in the early mornings and early evenings. Peak load indicates the additional demand placed on the system over and above the normal base load requirements. The country’s abundant and relatively cheap low-grade coal makes coal-fired power stations an attractive base load choice. South Africa’s inconsistent rainfall and limited water resources preclude the use of hydro-power stations for base load needs. Base load power can also be supplied by nuclear power stations and, in countries with abundant water resources, hydro power stations. Base load power stations are generally only shut-down for scheduled maintenance or emergency repairs. In addition, starting up these power station units requires large quantities of expensive fuel oil.
#LOOPCAD LOAD VS PEAK FULL#
They require a minimum period of 8 hours from cold start-up to full load. Two main categories of power stations can be identified: base load stations which supply electricity around the clock and peak load stations which can react swiftly to sudden increases or decreases in demand.Įskom’s National Control Centre draws on these different types of power stations to provide a balance between supply and demand.īase load power stations, largely coal-fired in South Africa, are designed to operate continuously at a steady load. Due to the fact that electricity demand is not constant, different types of power stations are required to meet this fluctuating demand. It is important that the amount of electricity needed at any point in time should be matched by the amount generated. Electricity cannot be stored, and must therefore be used as it is generated.
